An error message – fault code is appearing on my Ducted heating wall controller | Thermostat
a. If something has interrupted the heater’s operation and Error message appears on the screen, write it down. This code contains information that will help Technician to deal with the issue that requires attention.
b. Refer to error codes in your owner's manual. Usually there is a list of faults customers can rectify safely. Try to reset the Error by turning OFF the power supply to the unit at the power point located adjacent to the heater or press RESET button. This may reset the heater and restore it back to normal operation.
c. If the heater does not resume normal operation or the error message re-appears, It's an indication the heater is not operating due to a malfunction or fault with the electronic control module or other heater components.
When professional assistance is required, we are ready to help. Contact REPAIR Heating & Cooling and our Technicians will identify and solve the problem for you.
An error, service message or a fault code are appearing on my Evaporative cooling wall controller
a. If something has interrupted the cooler’s operation and Error message appears on the screen, write it down. This code contains information that will help Technician to deal with the issue that requires attention.
b. Refer to error codes in your owner's manual. Try to reset the Error by turning OFF the power supply to the unit at the power point located adjacent to the heater or press RESET button. This may reset the cooler and restore it back to normal operation.
c. If the cooler does not resume normal operation or the error message re-appears, It's an indication the cooler is not operating due to a dirty sensors, low water level or malfunction of electric or electronic components.
When professional assistance is required, we are ready to help. Contact REPAIR Heating & Cooling and our Technicians will identify and solve the problem for you.
Cooler leaking water continuously | High water usage | Water running down on the roof
For some older models or entry level evaporative air conditioners "bleed-off" a small measure of water while operating is normal. This is to prevent a build up of mineral deposits in the system. Also modern and high end model coolers are fitted with an automatic drain vale system which will discharge water at the end of cooling cycle. However, if water leak is significant or it's outside of operating cycle - might be there is a problem.
a. Water overflows. Check if water level setting is correct. Float valve, inlet solenoid, drain valve, water sensor or main control board can also be faulty.
b. Filter pads are damaged or misaligned. Re-align or replace pads.
c. Loose or worn out fittings and seals. Visually inspect for any damage to external or internal components. *** Subject to a licensed work only.
If you cannot find or seal the leak on your own, we are ready to help. Contact REPAIR Heating & Cooling and our Technicians will identify and solve the problem for you.
Cooling system display is blank | Wall control not working
POSSIBLE DIAGNOSIS:
a. The batteries are flat. Some Evap cooler models have a Remote control which require a batteries. Try to replace batteries with a fresh set. Do not forget to re-establish signal with receiver.
b. The circuit breaker has tripped or unit unplugged. Most of Controllers are getting power from the unit, If the circuit breaker trips, it may shut off the power to your cooler and screen will go blank. Check and reset circuit breaker in electrical box. But, do not repeat if the breaker trips again.
c. Blown fuse. Cooling unit has built-in fuse, when it's blown, the transformer will stop supplying voltage to the cooler's components. Replacing a fuse might help to restore power to the cooler and controller.
d. Loose Connections or Wiring Problems. Visually check wiring or connections for damage or oxidation. Also main control board could be faulty.
e. Faulty wall control. If all else fails, your wall control might need to be replaced. The average device has a life expectancy of around 15-20 years.
If you’ve noticed continued problems with a Cooling controller that keeps going blank, we are ready to help. Contact REPAIR Heating & Cooling and our Technicians will identify and solve the problem for you.
Ducted Heater blowing cold air | No longer blowing warm air
POSSIBLE DIAGNOSIS:
a. Gas supply interruption. Check the heater’s gas valve turned ON. If you have more than one gas appliance, find out if they are working.
b. The pilot light is off. If your heater was made before 1999, it probably still has a pilot light. There are instructions on a unit for how to relight it. However, you are dealing with gas and fire, so don’t do anything you’re not 100% comfortable with.
c. Overheat lockout due to a Restricted Air Flow. Listen for a whistle. If the heater can’t get enough air through the filter, it pulls air through any opening it can. A whistling sound is an indication of a problem. Check, clean or replace return air filter. Ensure minimum 7-10 outlets/vents are open, it's required for an adequate airflow.
d. Main control board in a safety lockout or malfunctioning. Switch ON/OFF power to the heater to reset Main control board.
If the unit is still blowing only cold air after trouble shooting all these steps, we are ready to help. Contact REPAIR Heating & Cooling and our Technicians will identify and solve the problem for you.
Ducted heater burners come on, but do not stay on | Burners keep going off
a. On classic natural draught flue appliances - the problem could be a gas valve or main control board.
b. If it's a fan forced flue type unit, and the burners come on but do not stay on for more than 5 seconds, the flame sensor could be dirty or a flame sensing circuit is bad.
c. On a high efficiency condensing heaters, it could be a ROLLOUT or a backfire signal due to a trapped condensateor a sediment build up in a heat exchanger.
All of the above can cause the heater to operate abnormally. This issues may require a professional assistance.
When professional assistance is required, we are ready to help. Contact REPAIR Heating & Cooling and our Technicians will identify and solve the problem for you.
Ducted heater has blank Thermostat screen | Wall control not working
POSSIBLE DIAGNOSIS:
a. The batteries are flat. Many Thermostats require batteries that need to be changed once every year. Try to replace batteries with a fresh set.
b. The circuit breaker tripped. Some thermostats are getting power from the heater, If the circuit breaker trips, it may shut off the power to your heater and screen will go blank. Check and reset circuit breaker in electrical box. But, do not repeat if the breaker trips again.
c. Blown fuse. Heating unit has built-in fuse, when it's blown, the transformer will stop supplying voltage to the heater's components. Replacing a fuse might help to restore power to the heater and thermostat.
d. Loose Connections or Wiring Problems. Visually check wiring or connections for damage or oxidation.
e. Faulty Thermostat. If all else fails, your thermostat might need to be replaced. The average device has a life expectancy of around 15 years.
If you’ve noticed continued problems with a thermostat that keeps going blank, we are ready to help. Contact REPAIR Heating & Cooling and our Technicians will identify and solve the problem for you.
Ducted heater has tripped power circuit breaker | Turned off safety switch
As a safety switch is designed to shield people from an electric shock, if it has tripped that usually means there is a leaking current or a short circuit within a faulty appliance.
It may be a quick and easy fix just by switching your safety switch back to ‘ON’. If you try this, and it flips back to ‘OFF’ instantly, then there is a solid reason to why it did happened, including :
a. Damaged wiring, fan motor or other electrical components within a ducted heater
b. If happens after heavy rainfall, could be an external power point is getting wet
c. Nuisance tripping, if too many appliances are running at once
d. A faulty safety switch, uncommon but can happen
If professional assistance is required, we are ready to help. Contact REPAIR Heating & Cooling and our Technicians will identify and solve the problem for you.
Ducted heating is very noisy | Making a strange noise
Whistling, humming, rumbling, squeaking noises and rattles aren’t normal. The sounds may indicate a mechanical problem or an airflow reductions.
a. Rattling noises - loose panels may need to be tightened.
b. Squealing or Grinding sounds - may indicate issue with the room or combustion fan motor.
If you cannot find or resolve noise issue on your own, we are ready to help. Contact REPAIR Heating & Cooling and our Technicians will identify and solve the problem for you.
Electric igniter is clicking, but the burners does not light up on Ducted heater
If you hear a rapid clicking noise and the burners does not light up. Ensure the gas supply is ON and it was not interrupted recently, check there is no air trapped in the gas pipe line. In other case the burners could be blocked, main control board or gas valve are faulty, also overheat switch could be the problem. This issue may require a professional assistance.
When professional assistance is required, we are ready to help. Contact REPAIR Heating & Cooling and our Technicians will identify and solve the problem for you.