Every year when the first cold mornings hit, we get the same call:
My gas ducted heater will not start. It was working fine last winter.
This is extremely common across all major brands including Brivis, Bonaire, Braemar, Omega and Vulcan. After sitting unused all summer, heaters often refuse to fire up when you need them most.
We recently attended a property in Taylors Hill where a 15 year old Brivis gas ducted heater was not responding to the wall control panel at all.
Why Gas Ducted Heaters Often Fail After Summer
After months of inactivity, ducted heaters can struggle to ignite. In this case, the heater had entered safety lockout mode.
What Is Safety Lockout?
Safety lockout occurs when the heater tries to ignite several times but fails to establish a flame.
To prevent unburnt gas from accumulating, the system shuts itself down and refuses to start until the fault is cleared.
Why Brivis ducted heating it not ignite?
The most common reason, especially after months of no use, is dust buildup or minor obstruction inside the burner assembly. Over summer, dust, debris, and even small cobwebs can settle inside. When winter comes and the heater tries to fire up, the flame does not establish properly, and the system locks out.
It sounds dramatic, but in most cases, it is not a major failure.
How We Fixed Brivis Ducted Heating
In this case, the solution was straight forward:
- Cleaned the internal burner assembly and components
- Checked ignition system operation
- Cleared the error from the PCB
- Restarted and tested full heater operation
- Performed natural gas leak testing
- Checked for carbon monoxide spillage
Once cleaned and reset, the heater started straight away and ran normally.